Lab Facilities

  •   Haematology
  •   Bio chemistry
  •   Hormones
  •   Microbiology
  •   Histopathology
  •   Serology
  •   Cytology

Water Collection Procedure

  •   Collect sample in clean glass or plastic container
  •   Collect at-least 1000 min Litre of sample to perform all tests (Physical Chemical and Bacteriological)
  •   Collect sample in separate sterile bottle for bacteriological test (100 ml)
  •   Hand pump with tube wells - collect sample pumps after a little pumping time
  •   Open well water - collect sample just below the water level
  •   Pipe water - collect sample from the open taps

Effluent Sample Collection Procedure

Proper safety precautions must be observed when collecting waste water samples

  •   Collect sample in clean glass or plastic container
  •   Sample will typically be collected either by directly filling the sample container or by using an automatic sampler or other device
  •   Collect at-least 2000 m1/2Litres of sample to perform all tests
  •   Collect sample in separate sterile bottle for bacteriological test (100 ml)
  •   During sample collection, if transferring the sample from a collection device, make sure that the device does not come in contact with the sample containers
  •   Place the sample into appropriate, labeled containers

Water Testing Interval

Bacteriological Test

  •   Hand pump with tube wells - once a month
  •   Open well water - once in two months
  •   Pipe water - once in two months

Chemical Test

  •   Before and after monsoon twice a year

Remedies

  •   Keep your surroundings clean around the water resources
  •   Water should boil at least 15 minutes before drinking purpose
  •   Use suitable filters for cleaning the water
  •   Disinfect with Bleaching powder 5 gm in 1000 Litre water/Chlorine tablets

Parameters and Their Remedies

Sl. No.ParametersRemedies

1.

pH
<6.5 Add lime
>8.5 Add Alum (Aluminium sulphate)
2.Turbidity
Add Alum (Aluminium sulphate) 5g in 1000L
3.TDS
Reverse Osmosis, Distillation.
4.Total Hardness
Water softener, Ion exchanger, Reverse Osmosis
5. Calcium
Ion exchanger, Reverse Osmosis
6.Magnesium
Ion exchange,Chlorination.Oxidizing filter
7.Total Alkalinity
Neutralization agent
8.Chloride
Activated carbon, Distillation, Reverse Osmosis
9.Fluoride
Activated Alumina, Distillation, Reverse Osmosis
10.Iron
Oxidizing filter, Green - sand mechanical filter
11.Nitrate
Ion exchange, Distillation, Reverse Osmosis
12.Sulphate
Ion exchange, Distillation, Reverse Osmosis
13. Coliforms
Chlorination, Distillation. Ultraviolet
14.Escherichia coli
Chlorination, Distillation, Ultraviolet

Ahalia Welcomes You



Diabetic Medicine
Orthopedic
Podiatry
Blood Bank
Radiology
Central Laboratory
General Medicine
Ophthalmology
Anesthesia
Plastic & Trauma

Hospital Address

P.O. Box : 120, Kanal Pirivu, Palakkad,Pincode - 678 557, Kerala, India

phone Number

Phone:+91-4923-225555
Fax:

working hours

Monday - Friday: 12:00am - 11:59pm
Saturday -Sunday: 12:00am - 11:59pm

keep in touch

We are happy to answer your questions at : mail.adh@ahalia.in